Ceram-Etch
Material Safety Data Sheet
Identity: Ceram-Etch
SECTION l
Manufacturer: GPI
Address: 13391 Murphy Road, Stafford, TX 77477
Emergency Telephone Number: 800-527-3250
Telephone Number for information: 1-765-643-1061
Date Prepared: 5/14/2007
SECTION II- Hazardous Ingredients
Hazardous Components :As defined by DFR 1910, 1200 Hydrofluoric acid - 9.5%
SECTION III - Physical Data
Boiling Point: 212 F.- 246 F.
Vapor Pressure (9 mm Hg.: 9-10 @ 25° C
Vapor Density (Air = 1): 1
Specific Gravity (Water = 1): 1.8
Melting Point: n/A
Evaporation Rate (Butyl Acetate 1): 1
Solubility in Water: ACID CINTENTS 100%
Appearance and Odor: PINK, VERY LITTLE ODOR
SECTION IV - Fire and Explosion Data
Flash Point (Method Used): Will not burn
Flammable Limits: N/A
Extinguishing Media: N/A
Special Fire Fighting Procedures: None
Unusual Fire and Explosion Hazards: None
SECTION V - Reactivity Data
Stability: Stable
Incompatibility (Materials to Avoid): N/A
Hazardous Decomposition or By-Products: N/A
Hazardous Polymerization: Will not occur
SECTION VI- Health Hazard Data
Routes of Entry:
inhalation?: Yes
skin?: Yes
ingestion?: Yes
Health Hazards (Acute and Chronic): Prolonged breathing of fumes may cause lung damage
May cause redness or burning
Eye contact may cause burning
Carcinogenicity: N/A
Signs and Symptoms of Exposure: Redness, burning sensation
Medical Conditions Aggravated by Exposure: N/A
Emergency and First Aid Procedures: Skin: flush with water. Eyes: flush with water for 15 minutes,
consult with physician. Ingestion: Do not ind7uce vomiting, give large amounts of water containing milk of magnesia, milk or olive oil.
SECTION VII- Precautions for Safe Handling and Use
Steps to Be Taken in Case Material is Released or Spilled: Flush area with water.
Waste Disposal Method: Neutralize with soda ash or lime and dispose of In
accordance with federal, state and local regulations.
Precautions to Be Taken in Handling and Storing: Rubber gloves are recommended.
Other Precautions: Protective glasses should be worn. Store in a cool area out of direct sunlight
SECTION VIII- Control Measures
Respiratory Protection: Use in a ventilated area.
Ventilation: No special exhaust system needed.
Protective gloves: Rubber gloves should be worn.
Eye protection: Wear protective glasses or eyewear.
|